CVE-2025-9231: ruggedcom rst2428p firmware before 4.0 (exclusive); +23 more affected products

CVE-2025-9231 affects openssl-3.5-libssl. CVSS 3.1 base score 5.9 (MEDIUM, Source advisory). EPSS 0.01598 (percentile 0.76164), scored 14-Nov-2026. Fixed version: 3.5.4-r0. Fixed version: 3.5.4-r0. Fixed version: 3.5.4-r0. Fixed version: 3.5.4-r0. Fixed version: 3.5.1-1+deb13u1. Fixed version: 3.5.0+e1.

Affected technology

ruggedcom rst2428p firmware · before 4.0 (exclusive)
siemens

openssl · from 1.0.2 (inclusive), before 1.0.2zm (exclusive)
openssl

openssl · from 1.1.1 (inclusive), before 1.1.1zd (exclusive)
openssl

openssl · from 3.0.0 (inclusive), before 3.0.18 (exclusive)
openssl

openssl · from 3.2.0 (inclusive), before 3.2.6 (exclusive)
openssl

openssl · from 3.3.0 (inclusive), before 3.3.5 (exclusive)
openssl

openssl · from 3.4.0 (inclusive), before 3.4.3 (exclusive)
openssl

openssl · from 3.5.0 (inclusive), before 3.5.4 (exclusive)
openssl

sidis secured smartplug firmware · before 7.26.0310 (exclusive)
siemens

sinec os · before 3.3 (exclusive)
siemens

simatic cn 4100 firmware · before 5.0 (exclusive)
siemens

OpenSSL · 3.5.0 to before 3.5.4, 3.4.0 to before 3.4.3, 3.3.0 to before 3.3.5, 3.2.0 to before 3.2.6
OpenSSL

RUGGEDCOM RST2428P · 0 to before V3.3
Siemens

RUGGEDCOM RST2428P · 0 to before V4.0
Siemens

SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family · 0 to before V3.3
Siemens

SCALANCE XCH328 · 0 to before V3.3
Siemens

SCALANCE XCM324 · 0 to before V3.3
Siemens

SCALANCE XCM328 · 0 to before V3.3
Siemens

SCALANCE XCM332 · 0 to before V3.3
Siemens

SCALANCE XRH334 (24 V DC, 8xFO, CC) · 0 to before V3.3
Siemens

SCALANCE XRM334 (230 V AC, 12xFO) · 0 to before V3.3
Siemens

SCALANCE XRM334 (230 V AC, 8xFO) · 0 to before V3.3
Siemens

SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) · 0 to before V3.3
Siemens

SCALANCE XRM334 (24 V DC, 12xFO) · 0 to before V3.3
Siemens

SCALANCE XRM334 (24 V DC, 8xFO) · 0 to before V3.3
Siemens

SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) · 0 to before V3.3
Siemens

SCALANCE XRM334 (2x230 V AC, 12xFO) · 0 to before V3.3
Siemens

SCALANCE XRM334 (2x230 V AC, 8xFO) · 0 to before V3.3
Siemens

SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) · 0 to before V3.3
Siemens

SIDIS Secured SmartPlug · 0 to before V7.26.0310
Siemens

SIMATIC CN 4100 · 0 to before V5.0
Siemens

Component: Not specified by the source

Attack conditions (Source advisory, CVSS 3.1): Network (remote) · No privileges required · No user interaction required

What an attacker can do

Source advisory’s CVSS 3.1 assessment (base score 5.9/10) rates confidentiality impact as high; integrity and availability impact as none. The description does not specify what an attacker can achieve beyond these rated impacts.

Published

CWE
CWE-385
Product
openssl-3.5-libssl
CCR priority
24.0 /100 (P4)
CVSS 3.1
5.9 /10 · CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N · Source advisory
EPSS
0.01598 · percentile 0.76164 · 2026-11-15
KEV
no