Get real-time updates on Telegram
CVE-2026-12851: GV-I/O Box 4E V2.09
CVE-2026-12851. CVSS 3.1 base score 9.1 (CRITICAL, Source advisory). EPSS 0.02703 (percentile 0.85838), scored 25-Oct-2026.
Affected technology
GV-I/O Box 4E · V2.09
GeoVision Inc.
Component: Not specified by the source
Function: can, is
Attack conditions (Source advisory, CVSS 3.1): Network (remote) · High privileges required · No user interaction required
What an attacker can do
An attacker can send a network request to trigger this vulnerability. `libNetSetObj.so` is an internal library used by various binaries on the device to configure the network stack (start and stop various services, configure IP, Netmask, gateway, dns, etc.) #### CNetSetObj::m_F_n_Set_DNS_Addr command injection The following function can take up to two addresses, performs no sanitization and then calls `system`. Source advisory’s CVSS 3.1 assessment (base score 9.1/10) rates confidentiality, integrity and availability impact as high.
- CWE
- CWE-78
- CCR priority
- 37.1 /100 (P4)
- CVSS 3.1
- 9.1 /10 · CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H · Source advisory
- EPSS
- 0.02703 · percentile 0.86182 · 2026-11-15
- KEV
- no
Provenance
- FIRST EPSS daily exploit-probability · Source record · observed 2026-11-16 06:41:02.068004+00:00 UTC
- NVD CVE API 2.0 · Source record · observed 2026-10-26 06:26:09.176872+00:00 UTC
Stable permalink: https://cybercodered.org/item/cve-cve-2026-12851.html